| Certification: | ISO, MSDS, CE |
|---|---|
| Thickness: | 3.0mm |
| Type: | Roofing and Waterproofing |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Item | Units | Requirements | Test Method | ||||
| Visible defects | - | Visible defects | EN 1850-1 | ||||
| Thickness | mm | ≥3.0 | EN 1849-1 | ||||
| Mass per unit area | 3 mm | Kg/m2 | ≥3.3 | EN 1849-1 | |||
| 4 mm | ≥4.3 | ||||||
| 5 mm | ≥5.3 | ||||||
| Length | m | 10±0.01 | EN 1848-1 | ||||
| Width | m | 1±0.01 | EN 1848-1 | ||||
| Straightness | mm/10 m | ≤20 | EN 1848-1 | ||||
| Maximum tensile force | Longitudinal | N/50 mm | ≥800 | EN 12311-1 | |||
| Transversal | ≥800 | ||||||
| Elongation at the maximum tensile force | Longitudinal | % | ≥35 | EN 12311-1 | |||
| Transversal | ≥35 | ||||||
| Maximum peel resistance of joint | N/50 mm | ≥75 | EN 12316-1 | ||||
| Average peel resistance of joint | ≥50 | ||||||
| Resistance to tearing(nail shank) | N | ≥250 | EN 12310-1 | ||||
| Dimensional stability | % | ±0.6 | EN 1107-1 | ||||
| Shear resistance of joint | N/50 mm | ≥400 | EN 12317-1 | ||||
| Flexibility at low temperature | ° C | -15 | EN 1109 | ||||
| Water tightness | k Pa | ≥60 | EN 1928 | ||||
| Flow resistance at elevated temperature | ° C | 130 | EN 1110 | ||||
| Resistance to impact | mm | 2000 | EN 12691 | ||||
| Resistance to static loading | kg | 15 | EN 12730 | ||||
| Artificial ageing behavior | Determination of visible defects | Blister | - | No blister | EN 13707 EN 1297 EN 1850-1 |
||
| Crack | - | No crack | |||||
| Hole | - | No hole | |||||
| Nake spots | - | - | |||||
| Reaction to fire | Class E | EN ISO 11925-2 EN 13501-1 |
|||||